Manifold Pressure/Vacuum Sensor: Service and Repair
Manifold Absolute Pressure (MAP) Sensor
Service Repair No - 18.30.56
Removal
1. Disconnect the battery ground cable.
2. Remove the air intake resonator.
3. Position the wiring harness aside.
^ Remove the 2 bolts.
4. Remove the manifold absolute pressure (MAP) sensor.
^ Disconnect the electrical connector.
^ Remove the Allen screw.
^ Discard the O-ring seal.
Installation
1. Install the MAP sensor.
^ Clean the components.
^ Install a new O-ring seal.
^ Tighten the Allen screw to 3 Nm (2 ft. lbs.).
^ Connect the electrical connector.
2. Attach the wiring harness.
^ Tighten the bolts to 10 Nm (7 ft. lbs.).
3. Install the air intake resonator.
4. Connect the battery ground cable.