Operation CHARM: Car repair manuals for everyone.

Knock Sensor: Testing and Inspection

INSPECTION

INSPECT KNOCK SENSOR




a. Continuity inspection.
1. Using an ohmmeter, measure the resistance between the terminals.

Resistance: 120 to 280 kOhms at 20 °C (68 °F)

HINT: If the resistance is not specified, replace the sensor.