Blower Motor: Service and Repair
Blower Motor:
BLOWER MOTOR
REMOVAL
1. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
HINT: At the time of installation, perform initialization.
NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
2. REMOVE BLOWER MOTOR
a. Disconnect the connector.
b. Remove the 3 screws and blower motor.
INSTALLATION
Installation is in the reverse order of removal.