Operation CHARM: Car repair manuals for everyone.

Canister Purge Solenoid: Testing and Inspection





COMPONENTS FOR VSV FOR EVAP

VSV FOR EVAP INSPECTION
1. REMOVE V-BANK COVER
2. REMOVE VSV
3. INSPECT VSV





A. Inspect VSV for open Circuit
Using an ohmmeter, check that there is continuity between the terminals.

Resistance: At 20°C (68°F) 30 - 34 Ohms

If there is no continuity, replace the VSV.
B. Inspect VSV for ground
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.
C. Inspect VSV operation





(a) Check that the air flows with difficulty from port E to F.





(b) Apply battery voltage across the terminals.
(c) Check that the air flows without resistance from port E to F.
If operation is not as specified, replace the VSV.
4. REINSTALL VSV

Torque: 18 N.m (185 kgf.cm, 13 ft.lbf)

5. REINSTALL V-BANK COVER