P1755
DTC P1755 Linear Solenoid for Lock-up Control Circuit Malfunction (Shift Solenoid Valve SLU)
CIRCUIT DESCRIPTION
The amount of current flow to the solenoid is controlled by the (*) duty ratio of the ECM output signal. The higher the duty ratio becomes the higher the Lock-up hydraulic pressure becomes during the lock-up operation.
(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then
(*) Duty Ratio = A/A+B x 100 (%)
DETECTING CONDITIONS
HINT:
- Refer to the chart for the wave form between terminals SLU+ and SLU- when lock-up function is not operating.
- Refer to the chart for the wave form between terminals SLU+ and SLU- when lock-up function is operating.
WIRING DIAGRAM
Step 1:
Step 2:
INSPECTION PROCEDURE