Troubleshooting
DTC P0125 INSUFFICIENT COOLANT TEMPERATURE FOR CLOSED LOOP FUEL CONTROLCIRCUIT DESCRIPTION
DTC Detecting Condition:
A thermistor built into the engine coolant temperature sensor changes the resistance value according to the engine coolant temperature.
The structure of the sensor and connection to the ECM is the same as the those of the intake air temperature sensor.
If the ECM detects the DTC P0115, P0117 or P0118, it operates the fail-safe functions in which the engine coolant temperature is assumed to be 80 °C (176 °F).
Step 1:
Step 2:
INSPECTION PROCEDURE
HINT:
- If different DTCs that are related to different systems are output simultaneously while terminal E2 is used as a ground terminal, terminal E2 may be open.
- Read freeze frame data using the hand-held tester or the OBD II scan tool, as freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, it is useful for determining whether the vehicle was running or stopped, the engine was warmed up or not, the air-fuel ratio was lean or rich, etc. at the time of the malfunction.