Clock: Testing and Inspection
CLOCK SWITCH INSPECTION
NOTE:
- Clock switch built with the hazard warning switch.
1. Disconnect the negative battery cable.
2. Remove the clock switch. Service and Repair
3. Verify resistance between the clock switch terminals.
- If the resistance is not as specified, replace the clock switch.
Between the terminal C-E resistance
4. Connect the positive battery to the clock switch terminal A, the negative battery to the clock switch terminal F.
5. Verify the LED illuminates.