GF83.25-P-2101-01GI Air Distribution Switch, Function
GF83.25-P-2101-01GI Air Distribution Switch, Function
- with CODE (580a) Automatic air conditioning
Function
The air distribution can be set manually or automatically:
- Manual
- Turning the air distribution switch
- Automatic
- Pressing the Auto button ( [AUTO] )
Turning the air distribution switch on the AAC pushbutton control module (N22) actuates the various air distribution actuators via air conditioner bus.
The following basic settings for air distribution are provided:
- Air flow from center and side vents
- Air flow at center, side, footwell and defroster vents
- [up arrow] Air outlet at the center, side and defroster vent
- [down arrow] Air flow at center, side and footwell vents
Apart from the 4 listed basic settings, a further 8 intermediate settings can be selected.