Operation CHARM: Car repair manuals for everyone.

Manufacturer Code Charts: 2060


[4] Check component G3/1 (O2 sensor downstream TWC).: Pump current The signal voltage is too high.


Possible cause:

- O2 sensor downstream from catalytic converter
Affected functions:

- Exhaust system

-------------------------------------------------

Test 1: There are no further test steps at present.

1. There are no further test steps at present.
Please contact the relevant hotline for your market.

1. No further information available.