Manufacturer Code Charts: 2521
[8] Check system 'Starter control'.: Start attempt without starter actuation
Possible cause:
- Starter actuation
Affected functions:
- Engine start
-------------------------------------------------
Test 1: Test starter control.
1. Test starter control.
Actual value: Terminal (50)
Test prerequisite
- Start engine.
Status of relevant actual value:
- Terminal 50 (input):Warning!
- Terminal 50 (output, starter actuation):Warning!
Set/actual value comparison
- ON
Question
- Is the actual value o.k.?
YES
The actual value is okay.Possible cause and remedy
- In the event of stored faults with a high fault frequency count or in the event of customer complaints, check lines and connectors for loose contact and corrosion..
- Replace component N10/1 (Driver-side SAM control unit with fuse and relay module).
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Check line(s) from component N3/9 (CDI control unit) to component N10/1 (Driver-side SAM control unit with fuse and relay module) as per wiring diagram.
- Test relay N10/1kL (Starter relay), replace if necessary.
End of test