GF82.35-P-3003GZ Washer Nozzles/Washer Nozzle Hose Heater, Function
GF82.35-P-3003GZ Washer Nozzles/Washer Nozzle Hose Heater, Function
Component Identification:
Function
The washer nozzle heater is switched on automatically if:
^ Circuit 61 "ON" (engine running stably) and
^ Circuit 15X "ON"
^ and an outside temperature of less than 5 °C is detected.
Switch off is accomplished automatically when:
^ Circuit 61 "OFF" (engine off) or
^ Circuit 15X "OFF" (engine off) or
^ an outside temperature of greater than 8 °C is detected.
Actuation of heating elements
The washer nozzle heater is actuated by the front SAM control unit.