125C00
The positive control deviation during boost pressure control is too high.
Possible cause:
- M16/6 (Throttle valve actuator)
- Charge air system
Affected functions:
- Power generation
-------------------------------------------------
Test 1: Inspect charge air system for leaks.
Test 2: Check component M16/6 (Throttle valve actuator).
1. Inspect charge air system for leaks.
Inspect charge air system for leaks.
Important notes
- The following test sequence has changed.
- Follow the test procedure precisely!
- The test must be performed with the engine oil cap removed.
Communication with ECU required
2. Check component M16/6 (Throttle valve actuator).
Check component M16/6 (Throttle valve actuator) by means of actuation.
Figure legend
- M16/6 (Throttle valve actuator)
- B5/1 (Charge pressure sensor)
- The muffler was removed from the picture to improve the view.
Test prerequisite
- Check connector on component M16/6 (Throttle valve actuator) for correct seating, contact and latching.
- Operate engine at idling speed.
Communication with ECU required