Operation CHARM: Car repair manuals for everyone.

116D00


There is an internal fault in component G3/2 (Oxygen sensor upstream of catalytic converter).


Possible cause:

- N3/9 (CDI control unit)
Affected functions:

- Power generation

-------------------------------------------------

Test 1: Internal fault N3/9 (CDI control unit)

1. Internal fault N3/9 (CDI control unit)
Possible cause and remedy

- Erase fault memory in control unit N3/9 (CDI control unit)
- If fault occurs once again, replace control unit N3/9 (CDI control unit).
End of test