AR91.40-P-0611-05RT Firing Removed Emergency Tensioning Retractors When Ignition Device Is Not Present
AR91.40-P-0611-05RT Firing Removed Emergency Tensioning Retractors When Ignition Device Is Not Present
Application of shop-made ignition cables
1 Fabricate ignition cables at least 10 m long with a pressure switch at the end.
2 Plug the 2-pin plug connector into the corresponding emergency tensioning retractor unit.
3 Connect ignition cables to the battery.
4 Press both pressure switches simultaneously.
Keep a distance of 10 m for safety.