Operation CHARM: Car repair manuals for everyone.

AR91.40-P-0611-05RT Firing Removed Emergency Tensioning Retractors When Ignition Device Is Not Present



AR91.40-P-0611-05RT Firing Removed Emergency Tensioning Retractors When Ignition Device Is Not Present






Application of shop-made ignition cables

1 Fabricate ignition cables at least 10 m long with a pressure switch at the end.
2 Plug the 2-pin plug connector into the corresponding emergency tensioning retractor unit.
3 Connect ignition cables to the battery.
4 Press both pressure switches simultaneously.

Keep a distance of 10 m for safety.