GF83.10-D-4150HD Rear Blower Regulator, Component Description
GF83.10-D-4150HD Rear Blower Regulator, Component Description
- with CODE (H08) High-performance air conditioning
A32/3 Rear heavy duty automatic air conditioning recirculation unit
A32/3a1 Blower regulator
A32/3m1 Blower motor
Location
The blower regulator is located in the rear heavy duty automatic air conditioning recirculation unit, which is integrated into the roof air duct.
Task
The blower regulator regulates the speed of the blower motor to match the setting of the blower stage using the rear blower control button (+) (S98s2) and the rear blower control button (-) (S98s3) which are integrated into the AAC [KLA] control and operating unit (S98).
Design
A transistor is integrated into the blower regulator.
Function
Depending on the setting made using the rear blower control button (+) and the rear blower control button (-) the blower regulator allows a specific voltage to get through to the blower motor and thus regulates the various blower motor speeds.