Operation CHARM: Car repair manuals for everyone.

13AA00


The supply voltage of control unit N3/9 (CDI control unit) is too high (overvoltage).


Possible cause:

- Supply voltage
Affected functions:

- Power generation

-------------------------------------------------

Test 1: Test voltage supply.

1. Test voltage supply.
Possible cause and remedy

- In the fault freeze frame data, check whether the power supply was OK at the time the fault occurred.
Battery voltage < 27 VReplace control module N3/9 (CDI control unit).Battery voltage >= 27 VIgnore fault code and erase fault memory.End of test