Operation CHARM: Car repair manuals for everyone.

Condenser Fan: Description and Operation

Dual electric fans are temperature controlled. fans are switched to low speed when refrigerant pressure is 20.4 square inches (20 bar) and in high speed when engine temperature reaches 221°F. At maximum speed both fans draw about 26 amps at 13 volts.