GF46.50-P-5000-01A SPS Solenoid Valve, Function
GF46.50-P-5000-01A SPS Solenoid Valve, Function
- with CODE (213a) Speed-sensitive power steering
The P-valve is actuaded in cycles with approx. 6V by the ETS, ASR or ESP control module (N47-1, N47-2, N47-5). As vehicle speed increases the current flow reduces and the P-valve opens the control restrictor continuously in accordance with a characteristic (K) defined in the control module. Consequently the oil flow is controlled and also the steering wheel torque.
If the valve is fully energized, (v=0 km/h), the control restrictor is closed. Consequently there is no oil flow and the lowest steering wheel torque is adjusted (parking situation).