Test 4A2: Perform Measurement at Component N3/10 (ME-SFI Control Module)
Perform measurement at component N3/10 (ME-SFI control module)
Test total resistance of the CAN engine
Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI control module).
- (4.1) 86<-->87 (4.2)
Specified value
- Resistor [55...65]
Question: Is the measured value okay?
No
- The measured value is not o.k.
Possible cause and remedy
- Cable from component N3/10 (ME-SFI control module) to component X63/4 (CAN databus adapter connector, 2-pin)
- Test terminating resistor of component X63/4 (CAN databus adapter connector, 2-pin).
- Test terminating resistor of CAN element in control module N3/10 (ME-SFI control module).
**End of test**
Yes
- The measured value is o.k.
**End of test**