P2095
No connection to component G2 (generator) (P0620)
Test 1: Check alternator interface to component G2 (generator).
1. Check alternator interface to component G2 (generator).
Test prerequisite
- The charge indicator lamp is lit.
Test sequence
- Switch on ignition.
- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).
- Measure direct voltage with multimeter between sockets [3.4] 37 and [3.02] 35 of the 126-pole socket box tester.
- Start engine.
Specified value:
- Voltage [11.0...14.5] V
Question:
- Is the measurement value OK?
YES
The measurement value is OK.End of test
NO
The measurement value is not OK.Possible cause and remedy
- Line from component G2 (generator) to component N3/10 (ME-SFI [ME] control unit)
End of test