Operation CHARM: Car repair manuals for everyone.

[1] Relays Starter: Short Circuit to Positive




[1] Relays Starter: Short circuit to positive

Check component Starter relay

Test prerequisite
- The starter does not rotate.

Test sequence
- Switch off ignition.
- Connect socket box to component N3/10 (ME-SFI control module).
- (4.7) 92<-->2 (5.2)
- Operate starter by means of drive switch.

Specified value
- Voltage [9.0...14.5] V

Question: Is the measured value okay?

No
- The measured value is not o.k.
Possible cause and remedy
- Test 'circuit 50' starter signal. (CAN message)
- N3/10 (ME-SFI control module)

Yes
- The measured value is o.k.
Further possible causes of fault
- Cable to component N10/1 (Front SAM control module with fuse and relay module)
- RelaysStarter
- Cable to component M1 (starter)
- M1 (starter)
End of test**