E2091
CAN message from control unit ESM or ISM is faulty.
Possible cause:
- A80 (Intelligent servo module for DIRECT SELECT)
Affected functions:
- CAN Communication
-------------------------------------------------
Test 1: CAN signal faulty
1. CAN signal faulty
Possible remedy
- Continue troubleshooting in control unit ISM.
- Read fault memory.