P0620
G2 (generator) : Alternator serial interface (P0620)
Possible cause:
- G2 (generator)
Affected functions:
- Battery / On-board electrical system
-------------------------------------------------
Test 1: Generator : Serial communication interface Test cable for open circuit.
1. Generator : Serial communication interface Test cable for open circuit.
Test prerequisite
- Relevant fault code exists or there is a complaint.
Test sequence
- Switch off ignition.
- Connect socket box (126-pin) to component N3/10 (ME-SFI [ME] control unit).
- Disconnect the socket 3 at control module N3/10 (ME-SFI [ME] control unit).
- Measure direct voltage with multimeter between sockets (3.04) 37 and (3.02) 35 of the 126-pole socket box tester.
Specified value
- Voltage > 3 V
Question
- Is the measurement value OK?
YES
The measurement value is OK.Possible cause and remedy
- If the case of stored faults which high fault frequency counter or in the case of customer complaints, inspect electric cables and connections for loose contact and corrosion.
End of test
NO
The measurement value is not OK.Possible cause and remedy
- Cable from component G2 (generator) to component N3/10 (ME-SFI [ME] control unit) has Short circuit to ground or open circuit.
- G2 (generator)
End of test