Blower Motor Resistor: Service and Repair
AR83.25-P-1220R Remove/Install Electronic Blower Regulator
1 Remove blower motor (A32m1)
2 Unscrew screws (1)
3 Use suitable tool to unclip locating tab of retaining clamps (2) and remove casing of blower motor (A32m1) and blower regulator (A32n1)
CAUTION: risk of fractures.
4 Detach blower motor (A32m1) from blower regulator (A32n1)
5 Install in the reverse order
6 Check blower regulator (A32m1) for proper operation.