GF54.30-P-2020RIA Settings on Workshop Level, Function
GF54.30-P-2020RIA Settings On Workshop Level, Function
Workshop level settings function sequence
Proceed as follows to access the workshop level:
- Close driver door
- Circuit 15R On
- Select basic menu display
- Press the instrument illumination brightness control and reset button (A1r1) three times within t = 1.5 s.
The left multifunction display (A1p13) then changes to the workshop level
The scroll forward/back button (S110s1) of the multifunction steering wheel can be used to scroll between the respective menus and submenus and in various lists.
The following information can be accessed:
- Voltage of on-board electrical system
- Data from instrument cluster (A1) (version numbers, software releases etc.)
- Chassis number
- Dynamometer test mode
Switching on and switching off dynamometer test mode in the instrument cluster is necessary for the roller dynamometer so that no fault is entered in the ESP, SPS [PML] and BAS control unit (N47-5).
In dynamometer test mode, it is possible to switch between the settings "ON" and "With circuit 15R OFF" using the scroll forward/ back button. If the "ON" setting is selected, the "Dynamometer test mode" screen is displayed again after a circuit change from "circuit 15R OFF" to "circuit 15R ON" (reminder message).
If the "With circuit 15R OFF" setting is selected, the display jumps to the screen which was last active before the workshop level was accessed after a circuit change from circuit 15R OFF to circuit 15R ON.