P240013
The switchover valve to the reference duct in the diagnostic module of the evaporative emission control system has a malfunction. There is an open circuit.
Possible cause:
- A101 (Tank leak diagnostic module)
Affected functions:
- Fuel system
-------------------------------------------------
Test 1: Check component A101 (Tank leak diagnostic module).
1. Check component A101 (Tank leak diagnostic module).
Test 1.1: Check power consumption of switchover valve of component A101 (Tank leak diagnostic module).
1.1. Check power consumption of switchover valve of component A101 (Tank leak diagnostic module).
Figure legend
- A -ConnectionTest cable 35-pin socket box
- 001 -Sockets of component N3/10 (ME-SFI [ME] control unit)
- 05 -35-pin socket box
- 050 -126-pin socket box
- 108 -Test cable 266 589 01 63 00
- N3/10 (ME-SFI [ME] control unit)
- II 1-63ConnectionTest cable
- III 64-126ConnectionTest cable
Warning!
- Connection A of test cable 108 may NOT be connected to connection B of the 126-pin socket box (050).
Continue to test with button F2
Test sequence
- Measure direct current with multimeter between sockets [F.4] 100 and [F.20] 116 of the 126-pole socket box tester.
- Switch on ignition.
Specified value
- Amperage[0.2...0.6] A
Question
- Is the measurement value OK?
YES
The measurement value is OK.Further possible causes of fault
- Check power consumption of pump motor of component A101 (Tank leak diagnostic module).
NO
The measurement value is not OK.Possible cause and remedy
- Test voltage supply of circuit 87.
- Check lines from component N3/10 (ME-SFI [ME] control unit) to component A101 (Tank leak diagnostic module).
- Inspect connector at component A101 (Tank leak diagnostic module) for damage, loose contacts and corrosion, repair if necessary.
- A101 (Tank leak diagnostic module)
End of test