E1417
Monitoring of signal 'Torque request' by control unit Traction systems has stopped.
Possible cause:
- N47-5 (ESP control unit)
Affected functions:
- Electronic stability program ESP
-------------------------------------------------
Test 1: Check component N47-5 (ESP control unit).
1. Check component N47-5 (ESP control unit).
Possible cause and remedy
- Read out fault memory of control unit N47-5 (ESP control unit).
End of test