Blower Motor: Service and Repair
Fig. 23 Blower Unit Attaching Bolt Locations:
1. Disconnect battery ground cable.
2. Remove glove box housing cover assembly, then lower crash pad assembly.
3. Disconnect resistor and blower motor electrical connectors.
4. Disconnect ventilation tube from blower motor.
5. Remove blower unit attaching fasteners, Fig. 23.
6. Pull blower unit out slightly, then disconnect Fresh/Recirc vacuum connector.
7. Remove blower motor from blower unit.
8. Reverse procedure to install.