Air Temperature Sensor ( Ambient / Intake ): Service and Repair
1. Apply sealant to threaded portion.
Specified sealant: Loctite 24200 or equivalent
2. Install intake air temperature sensor and tighten it to specified torque.
Sensor tightening torque: 7 Nm (5 ft.lbs.)
3. Fasten harness connectors securely.