Warning Lamps
If equipped with theft warning system, power is supplied at all times^ through 10 A fuse (No. (20) ,located in the fuse block)
^ to combination meter terminal (32) for the security lamp.
Ground for the security lamp is supplied when the system is activated
^ to combination meter terminal (39)
^ from terminal (2) of the theft warning control module.
With the ignition switch in the ON or START position, power is supplied
^ through 10 A fuse (No. (25) ,located in the fuse block)
^ to combination meter terminal (22) for the air bag warning lamp
^ to combination meter terminal (43) and
^ to combination meter terminal (2).
Ground is supplied for each of the warning lamps through different terminals of the combination meter.