Data Monitor
DATA MONITOROperation Procedure
1. After turning OFF the ignition switch, connect CONSULT-II and CONSULT-II CONVERTER to the data link connector.
CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.
2. Touch START (NISSAN BASED VHCL), ABS, DATA MONITOR in order on the CONSULT-II screen. If ABS is not indicated, go to GI-38, CONSULT-II Data Link Connector (DLC) Circuit. CONSULT-II Checking System
CAUTION: When START (NISSAN BASED VHCL) is touched immediately after starting the engine or turning on the ignition switch, ABS might not be displayed in the SELECT SYSTEM screen. In this case, repeat the operation from step 2.
3. Return to the SELECT MONITOR ITEM screen, and touch ECU INPUT SIGNALS, MAIN SIGNALS or SELECTION FROM MENU. Refer to the following information.
4. When START is touched, the data monitor screen is displayed.