With Manufacturer's Scan Tool
CONSULT-II OPERATIONCAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carries out CAN communication.
1. With ignition switch OFF, connect CONSULT-II and CONSULT-II CONVERTER to data link connector and turn ignition switch ON.
2. Touch "START(NISSAN BASED VHCL)".
3. Touch "BCM" on "SELECT SYSTEM" screen.
If "BCM" is not indicated, go to GI-38, "CONSULT-II Data Link Connector (DLC) Circuit". Schematic
4. Select item to be diagnosed on "SELECT TEST ITEM" screen.
ITEMS OF EACH PART