VDC Off Indicator Lamp
VDC OFF INDICATOR LAMPDescription
Component Function Check
1. VDC OFF INDICATOR LAMP OPERATION CHECK 1
Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.
Is the inspection result normal?
YES >> GO TO 2
NO >> Go to diagnosis procedure. Refer to "Diagnosis Procedure".
2. VDC OFF INDICATOR LAMP OPERATION CHECK 2
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the VDC OFF switch.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Check VDC OFF switch. Refer to BRC-197, "Description". VDC Off Switch
Diagnosis Procedure
1. CHECK VDC OFF SWITCH
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the VDC OFF switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Check VDC OFF switch. Refer to BRC-197, "Diagnosis Procedure". VDC Off Switch
2. CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-148, "CONSULT-III Function (ABS)". Consult-III Function (ABS)
Is the inspection result normal?
YES >> GO TO 3
NO >> Check items displayed by self-diagnosis.
3. CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to MWI-4, "Work Flow". Diagnosis and Repair Workflow
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit).
NO >> Repair or replace combination meter.