Refrigerant Pressure Sensor / Switch: Service and Repair
REFRIGERANT PRESSURE SENSORRemoval and Installation for Refrigerant Pressure Sensor
REMOVAL
1. Discharge the refrigerant. Refer to "HFC-134a (R-134a) Service Procedure".
2. Remove the front grille.
3. Disconnect the refrigerant pressure sensor connector and remove the refrigerant pressure sensor (1) from the liquid tank on the condenser.
CAUTION: Do not damage the condenser fins.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION: Replace the O-ring of the refrigerant pressure sensor with a new one, then apply compressor oil to it when installing it.