Precautions For Handling Leak Detector

Electronic Refrigerant Leak Detector




PRECAUTIONS FOR HANDLING LEAK DETECTOR
When performing a refrigerant leak check, use a electronic refrigerant leak detector (J-41995) or equivalent. Ensure that the instrument is calibrated and set properly per the operating instructions.

The electronic refrigerant leak detector (J-41995) is a delicate device. In order to use the electronic refrigerant leak detector (J-41995) properly, read the operating instructions and perform any specified maintenance.




1. Position probe approximately 5 mm (3/16 in) away from point to be checked.




2. When testing, circle each fitting completely with probe.




3. Move probe along component approximately 25 to 50 mm (1 to 2 in)/sec.