Operation CHARM: Car repair manuals for everyone.

Hazard Warning Lamps: Description and Operation

HAZARD LAMP OPERATION
Power is supplied at all times
- through 50 A fusible link (letter f, located in the fuse and fusible link box)
- to BCM terminal 70, and
- through 10 A fuse [No. 19, located in the fuse block (J/B)]
- to combination meter terminal 24

Ground is supplied
- to BCM terminal 67, and
- to combination meter terminals 10, 11 and 12
- through grounds M57, M61 and M79.

When the hazard switch is depressed, ground is supplied
- to BCM terminal 29
- through hazard switch terminal 2
- through hazard switch terminal 1
- through grounds M57, M61 and M79.
When the hazard switch is depressed, the BCM, interpreting it as hazard warning lamps are ON, outputs turn signal from BCM terminals 60 and 61.

The BCM supplies power
- through BCM terminals 60 and 61
- to front combination lamp LH and RH terminal 5
- through front combination lamp LH and RH terminal 10
- to grounds E15 and E24, and
- to rear combination lamp LH and RH terminal 3
- through rear combination lamp LH and RH terminal 5
- to grounds B7 and B19.

BCM sends signal to unified meter and A/C amp through CAN communication lines and turns on turn signal indicator lamps within combination meter.