With Intelligent Key System
BUZZER (COMBINATION METER)
Description
Performs operation method guide and warning with buzzer.
Component Function Check
1.CHECK FUNCTION
1. Use CONSULT-III to perform Active Test ("INSIDE BUZZER").
2. Touch "take out", "knob"or "key" to check that it works normally.
Is the inspection result normal?
Yes - Buzzer (combination meter) is OK.
No - SEE Diagnosis Procedure.
Diagnosis Procedure
1.CHECK METER BUZZER CIRCUIT
Meter Buzzer Circuit.
Is the inspection result normal?
Yes - GO TO 2.
No - Repair or replace harness.
2.CHECK INTERMITTENT INCIDENT
Intermittent Incident.
- INSPECTION END