P316F
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1. PRECONDITIONING
- Turn power switch OFF and wait at least 20 seconds.
- Make sure that 12V battery voltage is 11 V or more.
- GO TO 2.
2. PERFORM DTC CONFIRMATION PROCEDURE-I
1.Perform normal charging and wait at least 10 minutes.
2.Turn power switch ON.
3.Check DTC.
Is DTC detected?
YES- Proceed to "Diagnosis Procedure" .
NO (Without quick charge port)-INSPECTION END
NO (With quick charge port)-GO TO 3.
3. PERFORM DTC CONFIRMATION PROCEDURE-II
1.Turn power switch OFF.
2.Perform quick charging and wait at least 10 minutes.
3.Turn power switch ON.
4.Check DTC.
Is DTC detected?
YES- Proceed to "Diagnosis Procedure" .
NO- INSPECTION END
Diagnosis Procedure
1. CHECK ON-BOARD CHARGER OUTPUT POWER-I
With CONSULT
1.Turn power switch OFF.
2.Perform normal charging.
3.Turn power switch ON.
4.On the CONSULT screen, select "EV/HEV" - "DATA MONITOR" - "OBC OUT PWR".
Is value 0kW?
YES- GO TO 3.
NO-1 (with quick charge port)-GO TO 2.
NO-2 (without quick charge port)-Replace VCM. Refer to "Removal and Installation" Removal And Installation.
2. CHECK ON-BOARD CHARGER OUTPUT POWER-I
With CONSULT
1.Turn power switch OFF.
2.Perform quick charging.
3.Turn power switch ON.
4.On the CONSULT screen, select "EV/HEV" - "DATA MONITOR" - "OBC OUT PWR".
Is value 0kW?
YES- INSPECTION END (quick charger malfunction)
NO- Replace VCM. Refer to "Removal and Installation" Removal And Installation.
3. PERFORM SELF-DIAGNOSIS OF ON-BOARD CHARGER
Perform self-diagnosis of on-board charger.
Is any DTC detected?
YES- Check the DTC.
NO- Check to see if there is a factor causing a situation that battery charge does not start. Refer to
"Symptom Index" Symptom Index.