P318A
DTC Logic
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1. PRECONDITIONING
- Turn power switch OFF and wait at least 20 seconds.
- Make sure that 12V battery voltage is 11 V or more.
- GO TO 2.
2. PERFORM DTC CONFIRMATION PROCEDURE-I
With CONSULT
1.Turn power switch OFF and wait at least 20 seconds.
2.Turn power switch ON.
3.Shift selector lever in N range and wait at least 20 seconds.
4.Check DTC.
Is DTC detected?
YES- Proceed to "Diagnosis Procedure" .
NO- GO TO 3.
3. PERFORM DTC CONFIRMATION PROCEDURE-II
With CONSULT
1.Shift the selector lever to the entire position from P to D, and shift it to N position.
NOTE:
Hold the lever at each position for 3 seconds or more.
2.Check DTC.
Is DTC detected?
YES- Proceed to "Diagnosis Procedure" .
NO- INSPECTION END
Diagnosis Procedure
1. CHECK SELF-DIAGNOSTIC RESULT IN VCM
With CONSULT
Check self-diagnostic result in "EV/HEV".
Is DTC detected other than P318A?
YES- Check the DTC.
NO- GO TO 2.
2. CHECK SELF-DIAGNOSTIC RESULT IN ELECTRIC SHIFT CONTROL MODULE
Check self-diagnostic result in "SHIFT".
Are any DTC detected?
YES- Check the DTC.
NO- GO TO 3.
3. PERFORM DTC CONFIRMATION PROCEDURE AGAIN
1.Erase DTC.
2.Perform DTC confirmation procedure again. Refer to "DTC Logic" .
Is the DTC "P318A" detected again?
YES- Replace VCM. Refer to "Removal and Installation" Removal And Installation.
NO- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.