Front Power Window Switch
POWER SUPPLY AND GROUND CIRCUIT
FRONT POWER WINDOW SWITCH : Diagnosis Procedure
Regarding Wiring Diagram information, [1][2]Electrical Diagrams.
1. CHECK POWER SUPPLY CIRCUIT
Check voltage between power window and door lock/unlock switch
RH connector D105 terminal 10 and ground.
Is the inspection result normal?
YES- GO TO 3
NO- GO TO 2
2. CHECK HARNESS CONTINUITY
1.Turn ignition switch OFF.
2.Disconnect BCM connector M16 and power window and door lock/unlock switch RH connector.
3.Check continuity between BCM connector M16 (A) terminal 2
and power window and door lock/unlock switch RH connector
D105 (B) terminal 10.
4.Check continuity between BCM connector M16 (A) terminal 2 and ground.
Is the inspection result normal?
YES- Replace BCM. Service and Repair.
NO- Repair or replace harness or connectors.
3. CHECK GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect power window and door lock/unlock switch RH.
3.Check continuity between power window and door lock/unlock switch RH connector D105 terminal 11 and ground.
Is the inspection result normal?
YES- Inspection End.
NO- Repair or replace harness or connectors.