Refrigerant Oil Loss Due to A Large Leak
REFRIGERANT OIL LOSS DUE TO A LARGE LEAKIf the refrigerant charge is abruptly lost due to a large refrigerant leak, approximately 90 ml (3 fluid ounces) of refrigerant oil will be carried out of the system suspended in the refrigerant. Any failure that caused an abrupt refrigerant discharge will experience this oil loss. Failures that allow the refrigerant to seep or bleed off over time do not experience this oil loss.
Upon replacement of a component which caused a large refrigerant leak, add 90 ml (3 fluid ounces) of new 525 viscosity refrigerant oil plus the required amount of oil for the particular component (as outlined previously). Add the oil directly to the replaced component if possible. If the oil cannot easily be added to the replaced part, add the oil to the accumulator.