Operation CHARM: Car repair manuals for everyone.

Cornering Lamps

Voltage is applied at all times to the Turn/Hazard Switch Assembly through the I/P Fuse Block PERIMETER LT Fuse. The LH Cornering Lamp is permanently grounded to G104. The RH Cornering Lamp is permanently grounded to G105. When the Turn/Hazard Switch is in either LEFT turn or RIGHT turn, the corresponding lamp lights.