Insufficient Cooling
Due to its variable displacement feature, special caution is necessary when diagnosing insufficient cooling conditions with the V-5 compressor. It is normal for liquid refrigerant to collect in the compressor crankcase during extended periods of shutdown, therefore, cooling action may be delayed up to 2 minutes until the refrigerant is pumped from the compressor crankcase.
If you experience a delay in cooling upon start-up beyond 2 minutes, and the normal service manual procedure for A/C compressor clutch and electrical engine cooling fan operation has been accomplished, follow the procedure outlined below:
1. Operate the A/C system by setting to A/C mode and high blower.
2. Be sure the compressor clutch has engaged and that the electrical engine cooling fan is operating.
3. Idle the engine for 2 minutes with the A/C system operating.
4. If no cooling, run the engine at approximately 3000 rpm for 1 minute with the A/C system operating.
5. If no cooling, disengage the A/C for 1 minute at idle.
6. Set A/C system back to A/C mode, then run the engine at approximately 3000 rpm for 1 minute with the A/C system operating.
7. If no cooling, drive the vehicle in a normal manner for 5 minutes with the A/C operating.
8. If there is still no cooling, perform the VDOT A/C System Diagnostic Procedure. Testing and Inspection