TR Switch A/B/C/P
Scan Tool Displays HIGH or LOW. The Transmission Range
(TR) Switch A/B/C/P display represents the states of the four inputs from the transaxle range switch. HIGH displayed indicates a
B+ voltage signal being monitored at the
PCM. LOW displayed indicates a grounded input signal. The combination of transaxle range inputs indicates the position of the transaxle manual valve.