Sensor Inspection
VOLTAGE TESTING PROCEDURE:
1. Connect an analog voltmeter between terminal 1 and 3 of the crank angle sensor connector.
Terminal 3: Crankshaft Position signal
Terminal 1: Sensor ground
2. Measure the output voltage of the terminals while cranking the engine.
Standard Approximate Values 1.8 - 2.5v (needle fluctuates)
3. When the voltage is abnormal, check the sensor power and ground circuits.