Manual Transaxle
MANUAL TRANSAXLEThe Power Distribution Center ([1][2]PDC) supplies battery voltage to the engine starter motor solenoid through circuit T40 when the coil side of the engine starter motor relay energizes. Circuit T40 contains a 30 amp maxi fuse, and feeds the contact side of the engine starter motor relay. Both the 30 amp maxi fuse and the engine starter motor relay are located in the PDC.
The ignition switch supplies battery voltage to the coil side of the engine starter motor relay on circuit A41 when the key is moved to the START position and the operator has depressed the clutch pedal to close the clutch pedal position switch. Circuit Z1 grounds the coil side of the engine starter motor relay. When the coil side of the relay energizes, the contacts close, supplying battery voltage to the engine starter motor solenoid.
Circuit AO (battery positive cable) supplies battery voltage to the starter motor when the solenoid energizes.