Operation CHARM: Car repair manuals for everyone.

P0133

Tests 1 - 5:




Test 6:





SYMPTOM
P0133 - 1/1 O2 SENSOR SLOW RESPONSE

WHEN MONITORED
Start engine. Allow engine to idle. For 1st part of test, if limits are exceeded, test passes. If not, 2nd part of test runs. Ambient/Battery temperature >44 °F, Baro >22.13 "H2O, battery >10.5 volts, MAP >11.79 & <18.15 "H2O, RPM >1350 & < 2200 and VSS >50 and < 65 mph.

SET CONDITION
The oxygen sensor signal voltage is switching from below 0.39 volts to above 0.58 volts and back fewer times than required.

POSSIBLE CAUSES
- Exhaust leak
- O2 sensor sensor ground circuit voltage drop
- O2 sensor signal circuit voltage drop
- Wiring harness intermittent problem
- O2 sensor