Manifold Pressure/Vacuum Sensor: Service and Repair
Fig. 15 MAP/Air Temperature Sensor:
The MAP/IAT sensor mounts onto the left side of the intake manifold plenum.
REMOVAL
1. Disconnect the electrical connector from the MAP/Temperature sensor.
2. Remove screws from sensor.
3. Remove sensor.
INSTALLATION
1. Screw sensor to intake and tighten fasteners to 3 Nm (26.5 in. lbs.).
2. Attach electrical connector to sensor.