Condenser HVAC: Service and Repair
CAMARO & FIREBIRD
1. Discharge system refrigerant.
2. Disconnect coupled hose assembly and liquid line fittings.
3. Remove top radiator shield retaining screws, then remove upper condenser retaining screws.
4. After tilting radiator rearward, carefully lift condenser out of radiator support.
5. Reverse procedure to install, using new O-rings coated with clean 525 viscosity refrigerant oil. When installing new condenser, transfer mounting hardware from old unit.