DTC 23
Code 23 - Manifold Air Temp. (MAT) Sensor:
Wiring Diagram for Manifold Air Temp. (MAT) Sensor:
CODE 23 - MANIFOLD AIR TEMPERATURE SENSOR CIRCUIT (MAT) LOW TEMPERATURE INDICATED
Circuit Description:
The Manifold Air Temperature (MAT) sensor uses a thermistor to control the signal voltage to the Electronic Control Module (ECM). The ECM applies a voltage (about 5 volts) on CKT 472 to the sensor. When the air is cold, the sensor (thermistor) resistance is high, therefore, the ECM will see a high signal voltage. If the air is warm, the sensor resistance is low, therefore, the ECM will see a low voltage.
Test Description: Numbers below refer to circled numbers on the diagnostic chart.
Code 23 will set if:
^ A signal voltage indicates a manifold air temperature below -40~C (-40~F).
^ Boost conditions have been present for longer than 5 seconds.
Due to the conditions necessary to set a Code 23, the "Service Engine Soon" (SES) light will only stay "ON" while the fault is present.
1. A "Scan" tool may not be used to diagnose this fault, due to the ECM transmitting "default" (substitute) values, while the fault is present. A Code 23 will set, due to an open sensor, wire, or connection. This test will determine if the wiring and ECM are OK.
2. If the resistance is greater than 25,000 ohms replace the sensor.